2020年4月23日星期四

GDJS/GDJW High and Low Temperature Humidity Chamber is Designed According to IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold

The full name of IEC 60068-2-1 is Environmental Testing Part 2-1: Tests-Test A: Cold. It is edited by the IEC technical committee in 2008.We will introduce the IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold
The following is the original content of IEC 60068-2-1
IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold
This part of IEC 60068 deal with cold tests applicalbe to both non heat-dissipating and heat-dissipating specimens. For non heat-dissipating specimens, Tests Ab do not deviate essentially from earlier issues. Test Ae has been added primarily for testing equipment that requires being operational throughout the test, including the conditioning periods.
The object of the cold test is limited to the determination of the ability of components, equioment or other articles to be used, transported or stored at low temperature.
Cold tests cover by this standard do not enable the ability of specimens to withstand or operate during the temperature variations to be assessed. In this case, it would be necessary to use IEC 60068-2-14.
The cold tests are subdivided as follows:
- Cold tests for non heat-dissipating specimens
. with gradual change of temperature, Ab;
- Cold test for heat-dissipating specimens
. with gradual change of temperature, Ad,
. with gradual change of temperature, specimen powered throughout, Ae.
The procedures given is this standard are normally intended for specimens that achieve temperature stability during the performance of the test procedure.
LISUN designed the GDJS/GDJW High and Low Temperature Humidity Chamber according to the IEC 60068-2-1 standard. It is used to test the CFL/LED which meets IES LM-80-08, electricity products, electronic components, material and so on. We will update the procedure and testing parameters according to the updating of the IEC 60068 standard.

The following is the picture GDJS/GDJW High and Low Temperature Humidity Chamber

The following is the video of GDJS/GDJW High and Low Temperature Humidity Chamber


Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

2020年4月17日星期五

IK01-10 IK Level Tester is Designed According to IEC 60068-2-75: Tests- Test Eh: Hammer tests.

The full name of IEC 60068-2-75 is Environmental testing-Part 2-75: Tests- Test Eh: Hammer tests. It has been prepared by IEC technical committee 104:Environmental conditions, classification and methods of test. We will introduce the IEC 60068-2-75-1 Scope
The following is the original content of IEC 60068-2-75-1.
IEC 60068-2-75-1 Scope
This part of IEC 60068 provides three standardized and coordinated test methods for determining the ability of a specimen to withstand specified severities of impact. It is used, in particular, to demonstrate an acceptable level of electrotechnical items. It consists of the application to the specimen of a prescribed number of impacts defined by their impact energy and applied in the prescribed directions.
This part of IEC 60068 covers energy levels ranging from 0.14J (joules) to 50J(joules).
Three types of test apparatus are applicable to perform these tests. Annex C provides some guidance to this aspect.
Here is the IK level test (Impact Protection) rating table:
IK01
IK02
IK03
IK04
IK05
IK06
IK07
IK08
IK09
IK10
0.14J
0.2J
0.35J
0.5J
0.7J
1j
2j
5j
10j
20j
LISUN designed the Spring Impact Hammer IK Level Tester for IK01, IK02, IK03, IK04, IK05 and IK06 test. LISUN also designed the IK Level Tester for IK07, IK08, IK09 and IK10 test. All the equipment are designed according to the IEC standard. Because most of luminaires manufacturers are requested to do IK level test. We can also design other kinds of level tester according to the customers’ requires.
Degrees of protection against external mechanical impacts:
The following is the picture of IK01-10 IK Level Tester
ik level test

The following is the video of IK01-10 IK Level Tester

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

2020年4月3日星期五

Standard for testing ultraviolet intensity of UV (ultraviolet) lamps used for disinfection

The principle of ultraviolet disinfection is to use ultraviolet radiation to cause photolysis and denaturation of bacteria proteins, and the amino acids, nucleic acids and enzymes of bacteria are destroyed and died. At the same time, when the ultraviolet rays pass through the air, the oxygen in the air is ionized to generate ozone, which strengthens the bactericidal effect. Ultraviolet is mostly used for disinfection of air and objects, with a wavelength of 253.7nm. For air disinfection, the effective distance does not exceed Zm, the irradiation time is 30 ~ 60min, for the disinfection of items, the effective distance is 25 ~ 60cm, the irradiation time is 20-30min, and the timer starts from 5-7min when the light is on. In order to ionize oxygen in the air to produce ozone).

When the ultraviolet lamp used for disinfection is at a voltage of 220V, an ambient relative humidity of 60%, and a temperature of 20 ° C, the radiation intensity of 253.7nm ultraviolet rays should not be less than 70μw / cm2 Measurement, the special ultraviolet lamp is measured at the distance of use, the ultraviolet intensity meter used must be calibrated). The ultraviolet lamp's irradiation intensity gradually decreases during use, so the intensity of disinfecting ultraviolet rays should be measured frequently, once it drops below the required intensity; it should be replaced in time, so it is required to use an ultraviolet radiation meter to detect the intensity of ultraviolet radiation.

It is generally tested in accordance with the technical specifications of the UV lamp. The UV lamp manufacturer will provide the intensity description:

1.The center intensity at xx mm is as high as xxx μw / cm2, and it is sufficient to measure it with an ultraviolet light meter according to this data.
2.There will be a minimum intensity, and the minimum intensity of the effective irradiation area will reach xxx μw / cm2. According to this data, use an ultraviolet illuminance meter to measure.

Knowing the above UV intensity test standards for UV lamps that can be used for disinfection, we can know that the LPCE-2 (LMS-9000BUV) UV lamp test system of Shanghai Lishan meets the UV intensity test standards of UV lamps. LISUN LPCE-2(LMS-9000BUV) UV Lamp Test System is used to test the UV lamp (light source) Spectrum, Radiant, Efficiency, CRI, CCT, UVA, UVB, UVC radiant and electric parameters.Spectral Range Wavelength: 200-400nm(UV). The whole system includes the LMS-9000BUV High Precision UV Spectroradiometer,CFS-1.2M Silica Fiber,CASE-UV036 Dark Case for UV Test ,SLS-UV UV Standard Light Source with Calibrate Current (Optional).

Here is photo below shows the test system:
LMS 9000BUV
LMS 9000BUV

The following is the test report of this product for your reference:LMS 9000BUV Test Report LMS 9000BUV Test Report

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.
Tech Dep:
Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep:
Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

2020年3月24日星期二

LSG-5000 Goniophotometer is Designed According to EN 13032-16.1.1.3 Goniophotometer type 3

The full name of EN13032-1 is Light and lighting Measurement and Presentation of photometric data of lamps and luminaires. It is edited by CEN in 2004. This standard is a guide to procedures referring where necessary to the relevant CIE, ISO and CEN publications . We will introduce the clause 6.1.1.3 Goniophotometer type 3 in this article.

The following is the original content of EN 13032-1 6.1.1.3 Goniophotometer type 3.

6.1.1.3 Goniophotometer type 3

The light source is rotated around a vertical axis, a mirror arrangement around a horizontal axis. The photometer head is fixed.

The mirror shall not limit the view of the light source from the photometer head and to be plane. They should have a spectrally constant reflectance or their spectral reflectance shall be considered for the V(λ) correction of the used photometer head. Attention shall be paid to the polarization of the radiation due to reflection by the mirrors and the local situation of the reflection.

The goniophotometer of type 3 can be distinguished as follows:

1) Type 3.1:
a ) centre of mirror in rotation center;
b ) light source is rotated around the mirror on a fixed radius.

2) Type 3.2:
a ) light source in rotation center;
b ) the mirror is rotated around the light source on a fixed radius.

3) Type 3.3:
Light source and mirror are led on two oppositely orientated fixed radius around the rotation center.

LISUN designed the LSG-5000 Moving detector goniophotometer according to the EN 13032-1 Clause 6.1.1.3 standard. The measuring distance is from 5m to 30m. It can measure all types lighting sources, LED or HID luminaries such as indoor and outdoor luminaries. Roadway luminaries, street lamps, flood lights and other kinds of luminaries. And we also designed different kinds of dimension goniophotometer according to different sizes of tested samples. We will update the software and testing parameters according to the updating of the EN 13032-1 standard.

The following is the picture of LSG-5000 Goniophotometer:


LSG-5000CCD Moving Detector Goniospectroradiometer

The following is the video of LSG-5000 Goniophotometer:



Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.

Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

GDJS/GDJW High and Low Temperature Humidity Chamber is Designed According to IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold

The full name of IEC 60068-2-1 is Environmental Testing Part 2-1: Tests-Test A: Cold. It is edited by the IEC technical committee in 2008.We will introduce the IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold

The following is the original content of IEC 60068-2-1

IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold

This part of IEC 60068 deal with cold tests applicalbe to both non heat-dissipating and heat-dissipating specimens. For non heat-dissipating specimens, Tests Ab do not deviate essentially from earlier issues. Test Ae has been added primarily for testing equipment that requires being operational throughout the test, including the conditioning periods.

The object of the cold test is limited to the determination of the ability of components, equioment or other articles to be used, transported or stored at low temperature.

Cold tests cover by this standard do not enable the ability of specimens to withstand or operate during the temperature variations to be assessed. In this case, it would be necessary to use IEC 60068-2-14.

The cold tests are subdivided as follows:

- Cold tests for non heat-dissipating specimens

. with gradual change of temperature, Ab;

- Cold test for heat-dissipating specimens

. with gradual change of temperature, Ad,

. with gradual change of temperature, specimen powered throughout, Ae.

The procedures given is this standard are normally intended for specimens that achieve temperature stability during the performance of the test procedure.

LISUN designed the GDJS/GDJW High and Low Temperature Humidity Chamber according to the IEC 60068-2-1 standard. It is used to test the CFL/LED which meets IES LM-80-08, electricity products, electronic components, material and so on. We will update the procedure and testing parameters according to the updating of the IEC 60068 standard.
    
The following is the picture GDJS/GDJW High and Low Temperature Humidity Chamber

    
The following is the video of GDJS/GDJW High and Low Temperature Humidity Chamber


Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

2020年3月23日星期一

IK01-10 IK Level Tester is Designed According to IEC 60068-2-75

The full name of IEC 60068-2-75 is Environmental testing-Part 2-75: Tests- Test Eh: Hammer tests. It has been prepared by IEC technical committee 104:Environmental conditions, classification and methods of test. We will introduce the IEC 60068-2-75-1 Scope

The following is the original content of IEC 60068-2-75-1.

IEC 60068-2-75-1 Scope

This part of IEC 60068 provides three standardized and coordinated test methods for determining the ability of a specimen to withstand specified severities of impact. It is used, in particular, to demonstrate an acceptable level of electrotechnical items. It consists of the application to the specimen of a prescribed number of impacts defined by their impact energy and applied in the prescribed directions.

This part of IEC 60068 covers energy levels ranging from 0.14J (joules) to 50J(joules).

Three types of test apparatus are applicable to perform these tests. Annex C provides some guidance to this aspect.

LISUN designed the IK01-10 IK Level Tester according to the IEC 60068-2-75 standard. Because most of luminaires manufacturers are requested to do IK level test. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules(J).  IEC 62262 specifies the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. We can also design other kinds of level tester according to the customers’ requires.

The following is the picture of IK01-10 IK Level Tester


The following is the video of IK01-10 IK Level Tester



Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.

Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

How to test LED fixture for startup, rise time and flicker

In recent years, the LED market has been expanding, which is attributed to the unique characteristics of LED solid-state lighting products, such as good luminous efficiency, long service life and high reliability .Therefore, LED solid-state lighting products are increasingly favored by the market and consumers. But at the same time, because of the fast response speed of LED and the lack of thermal inertia and afterglow effect of traditional lamps, the LED is deeply affected by the current fluctuation, which directly affects the output of light flux.

The flicker of light source is the external reflection of the change of light flux. Therefore, the flicker of LED lighting products has attracted people's attention. In this regard, on December 14, 2012, the European Union (EU) officially issued regulation NO. 1194/2012 in its official gazette, "implementation details of directive NO. 2009/125/EC of the European parliament and the European council on ecological design requirements for directional lights, LED lights and related equipment". According to the European commission (EC) regulation NO244/2009 issued on March 18, 2009,the European parliament and the European council directive 2005/32/EC on the implementation of ecological design requirements for nondirectional household lamps, so far the eu has formed a complete mandatory ecological design requirements for LED lamps. Start-up time and rise time, as two indexes of functional requirements, are paid more and more attention by manufacturers in the industry.

We just talked about the flicker effect of LED lighting, but most of people don't know what it means. The essence of light source flicker is the fluctuation of light flux. Driven by ac or pulse dc, the light flux, illuminance or brightness of the light source change correspondingly with the periodic change of current amplitude. Human eyes and human brains react subjectively to this change. Usually, Flicker can be divided into Visible Flicker and Invisible Flicker according to people's feelings. When the frequency is more than 100Hz, the human eye cannot feel the flicker phenomenon, but it will still cause eye fatigue, headache, etc. This is the yan shan effect, which is generally believed to exist within 500Hz. For this purpose, ENERGY STAR lamps V1.0 draft 4 specifies the conditions for flickering used for all lamps and lanterns in the dimming performance requirements.

 As shown in the figure below:
How to test led fixture for startup, rise time and flicker

The allowed range of light source flicker is:

1. The frequency is not less than 120Hz;
2. F1<0.001 X frequency within the frequency range of 120hz-800hz
3. There is no requirement for F1 when the frequency is greater than 800Hz;
4. If the frequency is uncertain, PF<30%;

In addition, the output frequency of compact fluorescent light should be 20-30khz, or greater than 40KHz.

The essence of light source flicker is the instability of light flux. When detecting the fluctuation of light source with time, the change curve of brightness can be tested, and the change curve of light flux or illumination can be tested under the same conditions. ENERGY STAR (V1.0) specifies the measurement requirements of flicker:

1. Power supply and measuring instruments shall meet LM-79-08 requirements;
2. Multi-channel oscilloscope with storage function, and attenuation probe can be added when necessary. The sampling rate is greater than 2kHz and the sampling time is greater than 100ms.
3. Photometric probe, V(in)correction, and the corresponding time should meet the requirements;
4. For absolute photometry :to measure the absolute value ,a sphere of integration Is required; For relative photometry: ensure that the detector is able to measure relative light output and only receives light from the light to be measured.
5. Before measurement, the compact fluorescent lamp shall be aged for 100 hours, and it shall be preheated before measurement. LED lights do not need to be old, the ambient temperature is 25+/-5 degrees.

In order to meet the EU Erp energy efficiency index requirements, as well as IEC60969S self-ballasts for general lighting safety requirements and energy star requirements, LISUN developed LSRF-3 lamps start, rise time and flicker test system, in order to meet the LED lamps start time, rise time instrument strobe flash test requirements.

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing, Surge Generator, Electrical Safety Testing, Environmental Test Chamber, IP Waterproof Test Equipment, Dustproof Test Chamber, High and Low temperature Humidity Chamber, Plug and Switch Testing, AC and DC Power Supply.


Please feel free to contact us if you need any support.

Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096