2019年2月26日星期二

Disable Digital Signature Enforcement for 64bit WIN 7 8 10

Disable Digital Signature Enforcement for 64bit WIN 7 8 10


If the driver need be installed in 64 bit Windows System, it need have digital signature. While some driver don’t have digital signature and the PC can’t install this kinds of device. If you want to install this device in 64 bit Windows System, You need disable digital signature enforcement.


Our some equipment need disable signature enforcement, such as LMS-6000, LMS-7000 and LMS-9000 series spectroradiometer.
  1. For the 64 bit WIN7, We have a small program in the CD, like the picture below. We can disable digital signature by the CD.

  2. CD for disable digital signature

    The program named as below. Double click it.

Program name

3.  Then click ‘Next’



4. Click ’Enable Test Mode’ and go ‘Next’



5.  Restart your PC



6. For the 64 bit WIN8 & WIN10. We can disable the digital signature on the PC directly. First hold down ‘Shift’ key and then click ‘Restart’ as below picture.



7.  Enter ‘Troubleshoot’



8. Enter ‘Advanced options’



9.  Enter ‘Startup Settings’



10.  Click ‘Restart’



11.  Press ‘F7’



You can also watch the complete video as below:



 

 

 

 

2019年2月25日星期一

LISUN product corresponding to Saudi Arabia's latest standard SASO2902

LISUN product corresponding to Saudi Arabia's latest standard SASO2902


Recently Saudi Arabia released new LED standard SASO2902 for energy efficiency, functionality and labeling requirements for Lighting products. We have got the SASO2902 in 2017 which is draft and already produce some instruments for some of the Saudi Lab. Such as below products:

1. LPCE-2(9000B) High Precision Spectroradiometer Integrating Sphere System. It can test EEI, EEI, CRI, CCT, LUMEN ,edt. More details please check: https://www.lisungroup.com/product-id-340.html
2. LSRF-2 Lamp Start, Run-up time and Flicker Tester, which meet Table 13 (on page 27) in SASO2902. The LSRF-2 can be used with LISUN LPCE-2 High Precision Spectroradiometer Integrating Sphere System. More details please check: https://www.lisungroup.com/product-id-375.html
3. LSG-5000 LM-79 Moving Detector Goniophotometer. This test system can make the measurement of Luminous Intensity Distribution, Luminaries Efficiency, Luminance Distribution, Efficient Luminescence Angle, EEI, UGR and etc. The test result can be exported as CIE, IES, LDT and other format files. More details please check: https://www.lisungroup.com/product-id-210.html
4. SY2036 Aging and Life Test Rack which is special designed for Saudi Arab to meet SASO2902 in clause 5.2. More details please check: https://www.lisungroup.com/product-id-352.html
5. Lumen maintenence and endurance test system LEDLM-80PL LED Optical Aging Test Instrument, which meet SASO2902 in clause 5.2. More details please check: https://www.lisungroup.com/product-id-345.html

2019年1月21日星期一

Coupling Decoupling Network for Communication Lines

The COUPLING DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL HIGH SPEED COMMUNICATION LINES CDN61000-5C is designed for convenient surge testing with 1.2/50μs pulses, as defined in IEC / EN 61000-4-5 Ed. 3, it works with LISUN SG61000-5 Series Surge Generator.

Specification:
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP)
• Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.)
• Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode)
• Input and output interface: RJ45 connector
• Terminal layout (RJ45 connector):
First pair of lines: pins 1/2
Second pair of lines: pins3/6
Third pair of lines: pins 4/5
Fourth pair of lines: pins 7/8
• Max. operating speed: 1000MBit/s
• Max operating voltage: Max 50V DC
• Max operating current: Max 1A

Coupling Decoupling Network for Communication Lines

The COUPLING DECOUPLING NETWORK FOR UNSHIELDED SYMMETRICAL HIGH SPEED COMMUNICATION LINES CDN61000-5C is designed for convenient surge testing with 1.2/50μs pulses, as defined in IEC / EN 61000-4-5 Ed. 3, it works with LISUN SG61000-5 Series Surge Generator.

Specification:
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP)
• Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.)
• Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode)
• Input and output interface: RJ45 connector
• Terminal layout (RJ45 connector):
First pair of lines: pins 1/2
Second pair of lines: pins3/6
Third pair of lines: pins 4/5
Fourth pair of lines: pins 7/8
• Max. operating speed: 1000MBit/s
• Max operating voltage: Max 50V DC
• Max operating current: Max 1A

2019年1月17日星期四

HCAI-1 High Current Arc Ignition Tester

The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011<Safety of Information Technology Equipment>and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety.

The HCAI-1 is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machinery, power tools, electronic instruments, electrical instruments, information technology equipment, electrical affairs equipment, electrical connectors and accessories research, production and QC department. It also suitable used in insolating materials, engineering plastics or other solid combustible materials industry.

Specification:

  • Electrode materials: copper (electrostatic electrode), stainless steel (movable electrode);

  • Electrode size: ф3.2mm~ф3.5mm 30° chisel end (static electrode),
    ф3.0mm 60° cone end (moving electrode);

  • Electrode angle: 45° from the horizontal plane;

  • Test voltage: 220V;

  • Arcing current: 33±5%A (adjustable);

  • Arcing power factor: COSφ0.5±0.05 (adjustable);

  • Arcing speed: 254mm / s ± 25mm / s;

  • Arc ignition frequency: 40 times / min (adjustable);

  • Number of arcs: 200 times (1 to 9999 times, digital display, preset);

  • Sample size: 130mm*13mm*(2~12)mm;

HCAI-1 High Current Arc Ignition Tester

The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011<Safety of Information Technology Equipment>and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety.

The HCAI-1 is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machinery, power tools, electronic instruments, electrical instruments, information technology equipment, electrical affairs equipment, electrical connectors and accessories research, production and QC department. It also suitable used in insolating materials, engineering plastics or other solid combustible materials industry.

Specification:

  • Electrode materials: copper (electrostatic electrode), stainless steel (movable electrode);

  • Electrode size: ф3.2mm~ф3.5mm 30° chisel end (static electrode),
    ф3.0mm 60° cone end (moving electrode);

  • Electrode angle: 45° from the horizontal plane;

  • Test voltage: 220V;

  • Arcing current: 33±5%A (adjustable);

  • Arcing power factor: COSφ0.5±0.05 (adjustable);

  • Arcing speed: 254mm / s ± 25mm / s;

  • Arc ignition frequency: 40 times / min (adjustable);

  • Number of arcs: 200 times (1 to 9999 times, digital display, preset);

  • Sample size: 130mm*13mm*(2~12)mm;

HCAI-1 High Current Arc Ignition Tester

The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011<Safety of Information Technology Equipment>and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety.

The HCAI-1 is suitable for lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machinery, power tools, electronic instruments, electrical instruments, information technology equipment, electrical affairs equipment, electrical connectors and accessories research, production and QC department. It also suitable used in insolating materials, engineering plastics or other solid combustible materials industry.

Specification:

  • Electrode materials: copper (electrostatic electrode), stainless steel (movable electrode);

  • Electrode size: ф3.2mm~ф3.5mm 30° chisel end (static electrode),
    ф3.0mm 60° cone end (moving electrode);

  • Electrode angle: 45° from the horizontal plane;

  • Test voltage: 220V;

  • Arcing current: 33±5%A (adjustable);

  • Arcing power factor: COSφ0.5±0.05 (adjustable);

  • Arcing speed: 254mm / s ± 25mm / s;

  • Arc ignition frequency: 40 times / min (adjustable);

  • Number of arcs: 200 times (1 to 9999 times, digital display, preset);

  • Sample size: 130mm*13mm*(2~12)mm;