How to effective to measuring LED lamp Start, Run up time and Flicker

How to effective to measuring LED lamp Start, Run up time and Flicker


Due to the LED solid-state lighting products have good luminous efficiency, long life and high reliability unique characteristics, so it's became more popular by markets and customers. But at the same time, the LED solid lighting have fast response characteristics, it haven’t thermal inertia and afterglow effects, like traditional lamps, so it have big influence by current fluctuations, the current fluctuations affect the luminous flux output directly, the lighting flashing is the external expression of luminous flux change, that caused more and more people focus on lighting flashing issue. Dated 14th December, 2012, the EU officially released the (EU) NO 1194/2012 rules <Implementing rules of the European Parliament and the EU Council Directive 2009/125/EC on the eco-design requirements of directional lights, LED lights and related equipment requirements>.Compared with <European Parliament and Council Directive 2005/32/EC implementing rules for non-directional household lamps eco-design requirements> which posted by the European Commission Regulation (EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and eco-design requirements. Start and Run-up time as the two indicators functional requirements in the industry has been more emphasis by manufacturers.

We just talked about the LED solid lighting product's flicker effect, many people have no idea about this. The light source flashing is directly expression of luminous flux fluctuation, the light source is driving by AC current and pulsed DC current, luminous flux, illuminance or brightness change accordingly with the current amplitude of cyclical change. Normally, according to human eyes feeling, the flicker divided into Visiable Flicker and Invisible Flicker. When the frequency more than 100Hz, the human eyes can’t feeling the flicker, but it will cause eyestrain, headache etc, this is the flash effect, generally agreed that the flicker effect exists within 500Hz. For this issue, America Energy Star(ENERGY STAR lamps V1.0 draft 4 In the dimming performance requirements specified in the blink Conditions to be fulfilled, use all tools). As below figure:



Light source flashing allowed range:

1、Frequency less than 100Hz;
2、Within 120Hz-800Hz frequency range, the F1<0.001 X frequency;
3、Frequency more than 800Hz, F1 have no requirements;
4、Frequency is uncertain, PF<30%;
Besides, the CFL lamp output frequency range should at 20-30KHz, or more than 40KHz.

The nature of light source flicker is luminous flux output fluctuations. When measuring light fluctuates with time change, not only the brightness curve can be tested, but also can test luminous flux curve or illumination curve which are under the same conditions. ENERGY STAR(V1.0)make the rules to measuring flicker’s requirements:

1、Power and instrumentation are need meet the requirements of LM-79-08;
2、Multi-channel oscilloscope with memory function, necessary need to add attenuation probe. The sampling rate is more than 2kHz, the sampling time is more than 100ms;
3、Photo detector V(入) Correction, and need meet the requirements of the corresponding time;
4、For the absolute value of the metering(absolute photometry): Need use integrating sphere when measuring of the absolute value; For relative value metering(relative photometry): To ensure that the detector is capable of measuring the relative light output, and only receives light from the light source to be measured;

Before measuring, the CFL lamps need light on 100 hours at least and it’s need preheat before testing. LED lamp needn’t lighting on, the environmental temperature range should at 25+/-5 degrees.

To meet EU ErP rules and Energy Star requirements, Lisun developed LSRF-2 Lamp Start, Run-up time and Flicker Test System. The hardware of this system included PH3000 Transient Photometer, LSP-500VAC Programmable AC Power Source Meter, IS-MA series Integrating Sphere, DC3005 DC Power Source and SLS series Standard Lamp; the software of this system included LST-3000 Lamp Start and Run-up Time Test and FLK-3000 Lamp Flick Test. PH3000 Transient Photometer is developed base on rapid sampling techniques, it’s fully meet EU and Energy Star relevant requirements. Combined with computer, it can measuring and record the fast change luminous flux waveform and others parameters. PH3000 applied with 12 Bytes, the maximum sampling rate of 10M Hz high-speed A / D. The PH3000 also can used as common illuminometer which can be widely used in light flux, brightness, illumination, etc. photometric detection and measurement. LSP-500VAC Programmable AC Sine Wave Power Source is a high-power, low pure sine wave distortion, high stability, integrated power supply source table, it’s especially suitable for as test power supply of electronic ballasts, energy saving lamps and other small power household appliances. And this system also included IS-1.5MA Integrating Sphere, DC3005 DC Power Source and SLS-50W Standard Light Source.

2018年7月27日星期五

Wire and cableFlame Tester

Description:

 

Wire and cable Flame Tester is used to test and evaluate the combustion characteristics of single insulated wires or cables. This equipment meets the requirements of IEC60332-1-1、GB18380.11/12-2008、GB18380.1-2001、IEC60335-1(GB4706.1). The product tank shell is irony spray, and is resistant to smoke corrosion, the digital meter shows time. This device has beautiful appearance, is easy to use and has reliable performance.

 

Specification:

 

  1. Flame box: size of box: W300xH1200xD450mm

  2. Gas: High purity propane gas or petroleum liquefied gas (user-supplied)

  3. Tested wire and cable length: 600±25mm

  4. Tested wire and cable outer diameter: conductor diameter > 0.8mm or cross-sectional area > 0.5mm²

  5. The flame should be continuously burned: Burning time:0.1-999.9s ( continuously set)

  6. Gas Flow: 0.03~0.3ml/Min

  7. Air Flow: 3-30L/min

  8. Box material: irony spray

  9. Burning lamp standard power : 1KW

  10. Customer need to prepare air compressor

  11. Power supply and voltage: AC 220V 50HZ 5A

2018年7月22日星期日

Similarities and Differences between Photometric Measurements of Goniophotometer and Integrating Sphere for Solid State Lighting Products

Similarities and Differences between Photometric Measurements of Goniophotometer and Integrating Sphere for Solid State Lighting Products


According to the requirements of the LM-79 optical testing standards applicable to the widest range in the world, although there are many photometric measurements for light sources and lamps are available, but these standards are dedicated to the measurements for light sources and lamps. Because the form of current SSL products are lamps or luminaires, and LED in the luminaires is not easy to be replaced or separated, the existing standards cannot be directly applicable to SSL products, which requires the use of absolute photometry measurements. The photometric information required for SSL products is usually the total luminous flux (lm), luminous efficiency (lm/W), luminous intensity (Candela) in one or more directions, chromaticity coordinates, correlated color temperature and color rendering index.

There are two kinds of photometric measurement methods in LM-79: integrating sphere + spectroradiometer (or photometer); goniophotometer. Each of these two test systems has its own advantages and disadvantages. For different SSL (solid state lighting products), users can make their own choice. Two test methods for environmental temperature, air flow, power supply have specific requirements, please refer to the contents of LM-79 2.0~8.0.

For Integrating Sphere System:

Integrating sphere system is suitable for integrating LED lamps and relatively small LED light sources to measure total luminous flux and colorimetric parameters. Integrating sphere system has the advantages of fast measuring speed and no need darkroom.

The air flow inside the sphere can reach the minimum, and the temperature inside the sphere is not easily affected by the potential airflow in the temperature control room. However, the test temperature in the integrating sphere still needs to meet the requirements of temperature in LM-79 2.0~8.0. Lisun recommends using IS-XXMT series constant temperature integrating sphere to control the test temperature to 25°inside the sphere.

There are two use ways of integrating sphere, one is V(λ) corrected photometric detector, and the other is spectrum analyzer. Because the integral sphere photometer has V(λ) spectral response deviation, the first method will produce spectral mismatch error, and the second method has no spectral mismatch error theoretically. So now most of the widest spectrum system use spectroscopy measurement in the market, and Lisun recommends LMS-9000B using spectroscopy with spectrophotometric method modified after years of research and development, and if equipped with IS-XXMT constant temperature integrating sphere, it can guarantee the test precision.



When choosing the size of integrating sphere, it needs to take into account the power and shell size of SSL products. In general, for compact lamps, 1m integrating sphere can be chosen. But if the lamp power is more than 500W, 2m integrating sphere may be suitable.

In the choice of integral ball size, while taking into account the needs of power and shell size of SSL products, usually for compact lamps can choose integral ball 1 meter, and when the lamp power is more than 500W need to consider the use of integral ball 2 meters. At the same time, if using 4π test mode, the surface area of tested lamp needs to be less than 2% of the area of sphere reflective coating, such as for a 2m integrating sphere, it can only be used to test lamps no more than 30CM in length. When testing the lamp tube or the strip lamp, the length of the lamp cannot exceed 2/3 of the diameter of the integrating sphere

There is another very important step in the use of integrating sphere spectroradiometer system, that is, the self absorption correction. The response of the sphere system changes due to the absorption of light by the luminaire inside the sphere, and the error may occur when the size and shape of the light source are not consistent with the standard light source.

Self absorption correction is critical because the physical size and shape of the SSL product are usually different from the size and shape of the standard lamp. If the self absorption correction is not carried out, the lumen test results will be low.



According to the introduction we find that integrating sphere + spectroradiometer test system can carry the test in a very short time, and do not needs the darkroom, through integrating sphere diffuse reflection, the system can test the total luminous flux of lamps in all directions. But they also have some disadvantages: size of test luminaire should be small, the test result is affected by the standard lamp, and the test procedure is complicated (need to use the auxiliary lamp for self absorption correction), also it needs frequent calibration.

LISUN recommends that users use LPCE-2 (LMS-9000B) spectroradiometer integrating sphere system for testing light and compact lamps. Also after years of development, LPCE-2 system can carry the test automatically, and all parameters can be read via software. With the standard lamp calibrated by LISUN standard laboratory, the test accuracy can be guaranteed.

For Goniophotometer System:

The most important function of the goniophotometer is to test the intensity distribution and to export the IES/LDT file of SSL products, but the lumen parameters of the measured sample can also be obtained by calculation.According to the requirements of LM-79, only vertical goniophotometer with rotating mirror and rotating detector is in compliance with test requirements (e.g. LISUN LSG-3000/5000)



Other types of goniophotometer due to causes a change in the working position of the lamp, generally used in the laboratory is not recommended, but LISUN Rotary Center Goniophotometer LSG-1700B/1800B Series, through the use of high precision constant temperature detector and custom software, can greatly weaken the error.



There are two most obvious advantages of using goniophotometer for photometric measurement:

1.Its test result is absolute value, rather than with the integrating sphere system need contrast conversion by standard lamp. If it is used to test the large lamp, the accuracy will be greatly improved, and there is no need to use additional auxiliary lamp to do self absorption calibration.

2.All optical parameters can be measured by adding spectroradiometer and corresponding detector in the darkroom. And the test data is the parameters of each angle in the space, more convincing.

But in order to realize the multi-function and high-precision measurement, the use of goniophotometer also has many limitations:

1.According to the standard requirements, the distance between the detector and the measured lamp must be at least 5 times of the length of the longest axis of the measured lamp. For the tested lamp with light beam angle, the required length will be longer. For example, if you need to test a 1m lamp, then the length of the darkroom light path needs at least 5 meters, plus the equipment itself rotating and placing position, the overall length of the darkroom needs to reach about 8 meters.

2.Darkroom needs to be brushed using non-reflective black material, any reflective position may have an impact on the test results.

3.It takes longer time (longer testing time than the integrating sphere system) to complete the test.

According to the above description we can see that although the integrating sphere has the advantages of high testing speed, low environmental requirements, but the use of the goniophotometer system, especially goniophotometer system with the photometric detector and spectroradiometer can test all parameters of the SSL products, and also can export the IES/LDT file for the lighting design.

After years of experience and design, LISUN recommends users to test the bulb lamp, T5/T8 lamp, light source, small chip integrated lamps with spectroradiometer + integrating sphere test system (LPCE-2), and to test large lamp, street lamp, HID lamp with goniophotometer system (LSG-5000CCD/LSG-1800BCCD).

2018年7月20日星期五

LISUN Engineer Continue to do Installation and Training in Russia

LISUN engineer visit several customers in Russia this time. And the customer we discussed today purchased a LSG-1800B Rotation Luminaire Goniophotometer (Big Size) from LISUN this time.

LISUN engineer stay 2 days in our customer’s company for the installation and training. The customer is enthusiasm, and they expressed satisfaction with our service finally. It’s a happy trip here.

We share some photos with you below:

[caption id="attachment_10534" align="alignnone" width="1334"]Figure 1: Group photo of the customer and LISUN engineer(The left) Figure 1: Group photo of the customer and LISUN engineer(The left)[/caption]

[caption id="attachment_10535" align="alignnone" width="1334"]Figure 2: Group photo of the customer and LISUN engineer(The left) Figure 2: Group photo of the customer and LISUN engineer(The left)[/caption]

 

2018年7月15日星期日

Analysis on the Status of Certified LED Ball in USA Energy Star

Analysis on the Status of Certified LED Ball in USA Energy Star


Energy Star certification (Energy Star certification) is a certification which can adapt to the requirements of the United States Energy Department. In addition to UL, FCC certification, it is the most popular certification of lighting products to enter the United States market,. UL reflects the goods safety performance, FCC reflects the electromagnetic compatibility of products, while the Star Energy certification reflects the goods energy saving performance of the products. Especially for the current global energy shortage, the United States energy Department has promulgated a series of energy saving plan, and the promotion of energy saving products is the main activity.



Dated on October 2015, the United States on the market with a total 2995 bulb lamp products obtain the United States Energy Star certification, mainly used to replace the 25W, 40W, 60W and 100 watt ordinary lighting with incandescent, which won the 1563 kinds of LED bulb , LED ball was certificated in more than 190 companies.
The product size of the LED bulb is generally A19, A21 and A15 (A). The shape of the bubble is spherical, and the size of the bubble is 19*1/8. LED bulb lamp for E26, E26d, E12 and GU24.

The LED ball is licensed for 2 years, the time is short for years, most of the product warranty time is 3-5 years, and more than 10 years, and even individual enterprise warranty period is 15 years.



From the life of the product, the shortest have a nominal 1 hour, the longest 5 hours, 80% of the certified products nominal 25000 hours, the nominal 5 hours of business:



From the luminous efficiency, low 60lm/w, most of the LED bulb of the luminous efficiency of 80lm/w above, the highest for the 127.1lm/w, OPPLE products in the list, as shown below:



The amount of Chinese Certified companies have continued to increase, in more than 190 certified enterprises, Chinese enterprises occupied half, some domestic enterprises designed a variety of products won the energy star certification.

2018年7月13日星期五

LISUN engineer visit India to install & train LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System

One of LISUN engineers visited India to install and train for our customer here. The customer purchased LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System from LISUN.

LISUN Group’s products have been sold to more than 100 countries and regions in Europe, America, Australia, Africa and Asia. And we will continue presenting more and more high quality products to our customers in the future.

Then share a few photos:

[caption id="attachment_10504" align="alignnone" width="721"]Figure 1: LISUN engineer and the LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System Figure 1: LISUN engineer and the LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System[/caption]

[caption id="attachment_10505" align="alignnone" width="960"]Figure 2: Product installation has been completed Figure 2: Product installation has been completed[/caption]

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing,Electronic Ballast Tester, Electrical Safety Testing, Environmental Test Chamber, Plug and Switch Testing, AC and DC Power Supply and etc. Lisun Group wins thousands of customers’ trust with motto “Right Product, Right Price and Right Service”. Please learn more products here:http://www.lisungroup.com/article-id-47.html

2018年7月8日星期日

Russian installation training LSG-1800B high-precision rotating luminaire distributed photometer

LISUN engineers are always on the way to do installation & training all over the world. This article is about the installation and training in Russian. This customer is a large locally lighting manufacturer. Comparing the domestic and foreign suppliers, they finally choose our LSG-1800BHigh Precision Rotation Luminaire Goniophotometer and IS-2M Integrating Spheres.

We arrange engineer to visit this company to do installation and training as soon as they receive the equipment. The installation & training took two days. Our engineer communicate with customer in English. With the excellent professional knowledge and service attitude, our engineer was appreciated by customer.

 

Finally we share some photos:

[caption id="attachment_10485" align="alignnone" width="800"]Figure 1: LISUN engineer and the LSG-1800B High Precision Rotation Luminaire Goniophotometer Test System Figure 1: LISUN engineer and the LSG-1800B High Precision Rotation Luminaire Goniophotometer Test System[/caption]

[caption id="attachment_10486" align="alignnone" width="800"]Figure 2: LISUN engineer and theIS-2M Integrating Spheres Figure 2: LISUN engineer and theIS-2M Integrating Spheres[/caption]

 

Our main products are Goniophotometer, Spectroradiometer, Integrating Sphere, LED Test Instruments, CFL Test Instruments, Photometer and Colorimeter, EMC & EMI Testing,Electronic Ballast Tester, Electrical Safety Testing, Environmental Test Chamber, Plug and Switch Testing, AC and DC Power Supply and etc. Lisun Group wins thousands of customers’ trust with motto “Right Product, Right Price and Right Service”. Please learn more products here:http://www.lisungroup.com/article-id-47.html